EKLIS.CLIENT REPORT
F-04 · RESULT

Result management in depth

Everything between an instrument signal and a defensible answer. LABGEN's published strengths here (rule-based comments, invalid-result checking, panic push) are parity items; LABDAQ's auto-verification + delta engine and LigoLab's exception queues define the bar EKLIS targets.

What the benchmark ships

LABGEN / MEDFAR

Rules on results

Automated & manual entry, online result checking, verify/approve workflow, automatic invalid-result checking, rule-based test comments, age/sex-based normal ranges, panic reporting with smartphone push; microbiology susceptibility, pathology images, toxicology prescription-vs-result consistency.

BEST-IN-CLASS

LABDAQ engine

Auto-verification on lab-defined criteria with automatic delta checks against priors and a rules engine that now extends to microbiology — plus AI-generated explanations of what each rule does (v25.7, 2026).

THROUGHPUT MODEL

LigoLab exception queues

Auto-verification plus exception-based work queues is the pattern sold on volume-per-FTE and turnaround time — technologists see only what needs them.

EKLIS specification

GroupFeaturesPhase
CaptureBidirectional instrument capture with flag handling · batch/worksheet manual entry grids, keyboard-first · inbound reference-lab result mappingP1–P2
Auto-verificationRange checks · delta checks (absolute/percent, configurable lookback) · instrument flags · QC-status gating · critical-value exclusion · per-test enablement · versioned, auditable rule sets — every auto-release records the rule version that passed itP2
Review worklistsException-based queues (pending / held / delta / flagged) with hold reasons · every action attributed and audited · repeat/dilute workflowP1–P2
Critical valuesClosed-loop notification documentation: who was called, read-back, timestamp, escalation chain — never silently auto-releasedP2
Result contentFree-text + canned comments with rule-based auto-append · age/sex(/pregnancy)-specific reference ranges with effective dating · calculated results (eGFR, ratios) with formula versioning · absurd-value and unit blockingP1–P2
Corrections & historyCorrected results retain the original, are labeled, and re-deliver to every prior recipient · cumulative patient history and interval views · per-element audit trailP1
SpecialtyMicrobiology: organism dictionary, antibiotic panels, MIC/interpretation, cascade reporting, antibiogram output · image/PDF attachments at order, specimen, or result level · tox rx-vs-detected consistencyP4
CLIA §493.1291 — reports & corrections§493.1281 — result correlationCLSI AUTO10 / AUTO15CAP — annual auto-verification revalidation, critical-value documentation